Application
- Suitable for transferring liquids of low viscosity, non-inflammable and non-explosive, not containing solid particles or fibers
- Water supply & drainage for high-rise buildings, filtration and transfer at waterworks, pressure boosting in main pipe
- Washing and cleaning systems, boiler feeding, cooling water circulation, water treatment systems, auxiliary system, support equipment
- Ultra-filtration systems, reverse-osmosis systems, distillation systems, separators, swimming pools
- Agricultural irrigation: sprinkler irrigation, drip-feed irrigation
- Food & beverage industry
- Fire-fighting system
Operating Conditions
- Low viscosity, non-inflammable and non-explosive liquids not containing solid particles or fibers. The liquids must not chemically attack the pump materials. When pumping liquids with a density or viscosity is higher than that of water, a motor with a higher output power rating shall be used
- Liquid temperature: – 20℃ ~+ 120℃
- Flow ranges: 0.7- 120 m3 /h
- Liquid pH value: 4 – 10
- Max. ambient temperature: +40℃
- Max. operating pressure: 33 bar
- Altitude: up to 1000 m
Motor
- IE 2 motor (IE 3 motor optional)
- Totally enclosed & fan-cooled
- Enclosures class: IP55
- Standard voltage: 60Hz 1x220V / 3x380V
ldentification Codes

LVS: Stainless steel wetted parts
LVR: Cast iron base & pump cover
Identifications codes of flange structure
A: Oval flange K: Clamp connector
G: Threaded connector